Publication detail
Piezo-actuated device for a bio-structural monitoring application through vibration-based condition and electromechanical impedance measurements
BARCO, D. TINOCO, H. A.. CARDONA, C. I. PEÑA, F. M.
Original Title
Piezo-actuated device for a bio-structural monitoring application through vibration-based condition and electromechanical impedance measurements
Type
journal article in Scopus
Language
English
Original Abstract
This study presents a numerical and experimental development of a piezo-actuated device used for monitoring the stiffness variations of its support through electromechanical impedance measurements. The piezo-device and its components define a clamped beam system activated dynamically by two piezo-transducers that transmit vibrations to the support (monitoring substrate). An harmonic finite element analysis was carried out to understand the effects of the substrate properties on the dynamics of the piezo-device. Experimental tests corroborated the simulations with the correspondence of modal shapes and frequency response functions (FRFs) when the substrate varies its stiffness. A biomedical application was conducted in a bone specimen with three embedded teeth to monitor the stiffness variations induced by drillings in the bone. Results showed that the bone stiffness monitoring could be possible through the teeth due to that the drillings effect were quantified by electrical impedance signals.
Keywords
Biomedical applications, Electrical impedance,Electromechanical impedance, Experimental development, Frequency-response functions,Stiffness variations,Structural monitoring applications, Substrate properties
Authors
BARCO, D.; TINOCO, H. A..; CARDONA, C. I.; PEÑA, F. M.
Released
31. 10. 2019
Publisher
Institute of Physics Publishing
ISBN
1757-8981
Periodical
IOP Conference Series: Materials Science and Engineering
Year of study
657
Number
1
State
United Kingdom of Great Britain and Northern Ireland
Pages from
1
Pages to
7
Pages count
7
URL
BibTex
@article{BUT165772,
author="BARCO, D. and TINOCO, H. A.. and CARDONA, C. I. and PEÑA, F. M.",
title="Piezo-actuated device for a bio-structural monitoring application through vibration-based condition and electromechanical impedance measurements",
journal="IOP Conference Series: Materials Science and Engineering",
year="2019",
volume="657",
number="1",
pages="1--7",
doi="10.1088/1757-899X/657/1/012031",
issn="1757-8981",
url="https://iopscience.iop.org/article/10.1088/1757-899X/657/1/012031/meta"
}